SLP-308 Vacuum Tube Stereo
Preamplifier
Operation and Installation Manual
Please read this manual carefully before installing your new SLP-308 into your stereo
system. It contains important set up and installation information as well as safety
warnings regarding AC voltage inside the chassis.
SPECIFICATIONS: SLP-308 Stereo Tube Preamplifier
Dimensions: 17 1/8” W x 4 _” H x 14” D (~ 44 cm x 11.4 cm x 35.5 cm)
Weight: 15 lb. ( 6.8 kg)
Circuit: Class A Triode
Frequency Response: 9 Hz - 140 kHz + 0, - 3 dB
THD @ rated output: 0.02% (750 mV rated output, 12 volts maximum)
Input Impedance: 100,000 ohms resistive (100 K W)
Output Impedance: 440 ohms ( 440 W)
Gain: 12 dB
Signal/Noise Level: -88 dB
Resistors: 1 % metal film
Capacitors: Film and foil output caps, 5 micro farad (5 mFd)
Power Transformer: 200% continuous commercial duty cycle
Tubes: 2- 12AU7 dual triodes
Power Supply: Full wave rectification, center-tapped, pi-network with filter choke, fully
regulated
AC Power Requirements: 100 – 130 volts AC / 50-60 Hz at 24 watts
200 – 245 volts AC / 50-60 Hz at 24 watts
Internal Wiring: EE Teflon dielectric Silver wire
Warm-up Time: 5 minutes (1 minute auto mute)
Input and Output Jacks: Gold plated with Teflon dielectric inserts
Duty Cycle: Continuous duty 24 hours per day
This section describes the basic specifications of the SLP-308 at the time of printing. Specifications are
subject to change or improvement without notice or obligation.
FRONT PANEL FEATURES
Power Switch: 2 position toggle switch off/on controls the AC line voltage
Mute: Terminates (quiets) the output, also operated via remote hand set
Input Select: 4 position rotary switch controls relay input switching
Tape Monitor: 2-position toggle switch engages tape loop circuit
Listening Level: Motorized volume control, manual or via remote, with additional
blue indicator LED in the volume knob.
Dual Output Level Meters: These show output level voltage to the power amplifier, 0
dB is equivalent to 0.775 volts output.
On LED: Indicates internal power supply is power up
Operate LED: Indication of time delay release (approximately 1 minute)
Down LED: Lights up red as remote volume is turned to a lower setting.
Up LED: Lights up blue as the remote volume is turned to a higher setting.
REAR APRON FEATURES
AC Connector: Inlet for the detachable AC power cord, standard IEC plug
AC Fuse: !!VERY IMPORTANT!! ONLY USE 1 AMP Slow Blow FUSE
Remote Trigger: Female 2 circuit jack, 12 VDC @ 400 ma., On when power is on.
Dual Preamp Outputs: Connect to inputs of power amp or powered subwoofer
Tape Out: Constant output of selected input signal for recording, independent of
volume control setting.
Tape In: This is the tape monitor selected input. For use with recording devices that
employ a monitor system to hear the actual recorded signal. May also be used as an
additional line input or an input for an equalizer or other signal adapting device.
CD, Aux1, Aux2 and Tuner: These are inputs requiring line level inputs from source
components. These inputs have wide bandwidth, flat frequency response.
INSTALLATION AND UNPACKING
WARNING!
MAKE NO ATTEMPT TO PUT THE SLP-308 PREAMPLIFIER IN SERVICE
WITH THE COVER OFF THE UNIT. CONTACT WITH THE AC
VOLTAGE INSIDE THE SLP-308 CAN BE FATAL!
All our shipping cartons have been especially designed to protect their contents and
special care has been taken to prevent damage under normal conditions. Mishandling
should be evident upon inspection of the shipping container. If damage is found after
visual inspection, do not destroy the evidence. If necessary, document the damage with
photographs and contact the transport carrier immediately.
Carefully remove your new SLP-308 from its packing carton and examine it closely for
signs of shipping damage. It is recommended to save all original packing cartons to
protect your preamplifier should you wish to store it or ship it for after-sales service.
WARRANTY CARD
If you are the original USA purchaser of this preamplifier and purchased it for use within
the United States, you should fill out the enclosed warranty registration card and return
it to Cary Audio Design, within 15 days of your purchase. Warranty restrictions and
applications may apply. Consult the warranty section of this manual. Export models
operated outside the USA are covered by local warranties assigned by your local Cary
Audio distributor.
SLP-308 PLACEMENT
The SLP-308 is designed for use inside of homes. It must be protected from the
elements and temperature extremes. For example, avoid placing the unit in extremely
hot locations such as near or on top of radiators or other home heating devices. Its
location among the user’s home audio components is not critical.
POWER REQUIREMENTS
The SLP-308 is designed to operate from AC house current mains. The design voltage is
120 Volts AC at 50/60 Hz. Export units have settings for 100/200/220/240 Volts AC at
50/60 Hz.
INTERCONNECT CABLES
The interconnect cables from the output jacks of the SLP-308 to the input jacks on the
power amplifier can be any convenient length your set up requires. The choice of a high
quality interconnect cable is important. Your Authorized Cary Audio Design Dealer will
have proper interconnect cables in stock for this purpose. The low output impedance of
the SLP-308 will run long interconnect wire runs, as long as 30-40 ft., without a
problem. We suggest wires with good shielding if you live near transmitter towers for
TV or radio stations.
OPERATION
Your new SLP-308 preamplifier is ready for operation after the various interconnect
cables have been installed and the unit is plugged into the household AC mains 120 Volt
AC wall socket. The SLP-308 is provided with functional, useful front panel controls
with an attractive and logical layout.
POWER SWITCH
The toggle power switch is located at the left side on the SLP-308 preamplifier front
panel. The switch operates in the following manner:
OFF (Down position) Removes all AC voltages from the SLP-308 power supply.
ON
(Up position) Turns on the AC voltage to the power transformer primary
on. The power transformer has a 200% duty cycle. In simple terms,
the transformer is capable of operating two (2) SLP-308 preamplifiers
continuously 24 hours a day. We recommend that the AC power
switch be left in the ON position at all times. The SLP-308 sounds
much better after 100 hour burn in and when warmed up for _ hour.
Operate LED This blue LED will light after the SLP-308 is warmed up and
biased properly.
VOLUME CONTROL
The gain of both left and right channels is controlled simultaneously by this control. The
control potentiometer is of such high quality that the tracking error is less than 0.5 dB
from 0 to -60 dB. The program source remains in balance over the entire range of this
control. The taper rate of the volume control has been chosen to provide a rapid
increase in gain over the first half of rotation and slower gain increase above 12:00
position. The volume pot is controlling the input signal to the first grids of the 12AU7
tubes. The volume control has a DC motor attached for remote operation. The blue
LED in the volume knob is confirmation at a glance as to the overall level when you are
too far away to read the output level meters.
SELECTOR SWITCH
The 4-position rotary switch connects a choice of input program source, both channels
simultaneously. All program line sources are selected from this front panel 4 position
switch. As you switch from source to source inputs, you will hear a soft mechanical
clicking sound. This is normal and proper. The clicking sound is from the double pole,
double throw (DPDT) gold plated relays switching input positions.
WARNING!!!
MAKE NO ATTEMPT TO PUT THE SLP-308 INTO SERVICE WITH THE
TOP OFF OR THE CABINET OPEN. NEVER OPERATE THE SLP-308
WITH THE TOP COVER REMOVED. CONTACT WITH THE
OPERATING VOLTAGES PRESENT INSIDE THE SLP-308 CAN BE
FATAL!
FACTORY SERVICE
If it becomes necessary to replace any parts in the SLP-308, the same brand and part
number and style should be used. New parts are available from Cary Audio Design, Inc.
1020 Goodworth Drive, Apex, North Carolina, 27539.
Careful consideration has been given to the design of your new SLP-308 preamplifier to
keep maintenance problems to a minimum; however, it is possible that some problems
may arise. If this occurs, we suggest contacting our Customer Service Department at
phone number 919-355-0010 from 1 to 5 PM, East Coast time to describe your
problem in detail. Do not return the SLP-308 to the factory without a Return
Authorization Number (RMA number) from the Customer Service Department. As the
packing and shipping is being done by others, Cary Audio Design will assume no
responsibility if the transportation company refuses to pay a damage claim due to your
improperly packing or for lack of insurance should the unit be lost or damaged in
shipment from you to us.
SPECIAL NOTE:
Your new SLP-308 preamplifier is a polarity inverting design. This means that a positive
direction musical signal coming into the SLP-308 will be polarity inverted as it is
amplified and be sent to the power amplifier as a negative direction signal. The SLP-308
has one gain stage and one buffer stage in each channel. Absolute polarity inversion is
common on many high-end preamplifiers. If you are concerned about ‘Absolute Phase’
in your system, reverse the positive and negative leads either on the back of BOTH
loudspeakers or at BOTH the speaker output terminals of your power amplifier.
Remember to do this for both channels. However, please remember to switch the
phasing only at the amplifier or only at the loudspeaker, not at both places. Operating in
the polarity inverted phase mode will not harm anything.
Cary Audio Design
1020 Goodworth Drive
Apex, North Carolina 27539
Tel: 919-355-0010
Fax: 919-355-0013
|