Cary Audio Design Stereo Amplifier SLP 308 User Manual

SLP-308 Vacuum Tube Stereo  
Preamplifier  
Operation and Installation Manual  
Please read this manual carefully before installing your new SLP-308 into your stereo  
system. It contains important set up and installation information as well as safety  
warnings regarding AC voltage inside the chassis.  
 
SPECIFICATIONS: SLP-308 Stereo Tube Preamplifier  
Dimensions: 17 1/8” W x 4 _” H x 14” D (~ 44 cm x 11.4 cm x 35.5 cm)  
Weight: 15 lb. ( 6.8 kg)  
Circuit: Class A Triode  
Frequency Response: 9 Hz - 140 kHz + 0, - 3 dB  
THD @ rated output: 0.02% (750 mV rated output, 12 volts maximum)  
Input Impedance: 100,000 ohms resistive (100 K W)  
Output Impedance: 440 ohms ( 440 W)  
Gain: 12 dB  
Signal/Noise Level: -88 dB  
Resistors: 1 % metal film  
Capacitors: Film and foil output caps, 5 micro farad (5 mFd)  
Power Transformer: 200% continuous commercial duty cycle  
Tubes: 2- 12AU7 dual triodes  
Power Supply: Full wave rectification, center-tapped, pi-network with filter choke, fully  
regulated  
AC Power Requirements: 100 – 130 volts AC / 50-60 Hz at 24 watts  
200 – 245 volts AC / 50-60 Hz at 24 watts  
Internal Wiring: EE Teflon dielectric Silver wire  
Warm-up Time: 5 minutes (1 minute auto mute)  
Input and Output Jacks: Gold plated with Teflon dielectric inserts  
Duty Cycle: Continuous duty 24 hours per day  
This section describes the basic specifications of the SLP-308 at the time of printing. Specifications are  
subject to change or improvement without notice or obligation.  
FRONT PANEL FEATURES  
 
Power Switch: 2 position toggle switch off/on controls the AC line voltage  
Mute: Terminates (quiets) the output, also operated via remote hand set  
Input Select: 4 position rotary switch controls relay input switching  
Tape Monitor: 2-position toggle switch engages tape loop circuit  
Listening Level: Motorized volume control, manual or via remote, with additional  
blue indicator LED in the volume knob.  
Dual Output Level Meters: These show output level voltage to the power amplifier, 0  
dB is equivalent to 0.775 volts output.  
On LED: Indicates internal power supply is power up  
Operate LED: Indication of time delay release (approximately 1 minute)  
Down LED: Lights up red as remote volume is turned to a lower setting.  
Up LED: Lights up blue as the remote volume is turned to a higher setting.  
REAR APRON FEATURES  
AC Connector: Inlet for the detachable AC power cord, standard IEC plug  
AC Fuse: !!VERY IMPORTANT!! ONLY USE 1 AMP Slow Blow FUSE  
Remote Trigger: Female 2 circuit jack, 12 VDC @ 400 ma., On when power is on.  
Dual Preamp Outputs: Connect to inputs of power amp or powered subwoofer  
Tape Out: Constant output of selected input signal for recording, independent of  
volume control setting.  
Tape In: This is the tape monitor selected input. For use with recording devices that  
employ a monitor system to hear the actual recorded signal. May also be used as an  
additional line input or an input for an equalizer or other signal adapting device.  
CD, Aux1, Aux2 and Tuner: These are inputs requiring line level inputs from source  
components. These inputs have wide bandwidth, flat frequency response.  
 
INSTALLATION AND UNPACKING  
WARNING!  
MAKE NO ATTEMPT TO PUT THE SLP-308 PREAMPLIFIER IN SERVICE  
WITH THE COVER OFF THE UNIT. CONTACT WITH THE AC  
VOLTAGE INSIDE THE SLP-308 CAN BE FATAL!  
All our shipping cartons have been especially designed to protect their contents and  
special care has been taken to prevent damage under normal conditions. Mishandling  
should be evident upon inspection of the shipping container. If damage is found after  
visual inspection, do not destroy the evidence. If necessary, document the damage with  
photographs and contact the transport carrier immediately.  
Carefully remove your new SLP-308 from its packing carton and examine it closely for  
signs of shipping damage. It is recommended to save all original packing cartons to  
protect your preamplifier should you wish to store it or ship it for after-sales service.  
WARRANTY CARD  
If you are the original USA purchaser of this preamplifier and purchased it for use within  
the United States, you should fill out the enclosed warranty registration card and return  
it to Cary Audio Design, within 15 days of your purchase. Warranty restrictions and  
applications may apply. Consult the warranty section of this manual. Export models  
operated outside the USA are covered by local warranties assigned by your local Cary  
Audio distributor.  
SLP-308 PLACEMENT  
The SLP-308 is designed for use inside of homes. It must be protected from the  
elements and temperature extremes. For example, avoid placing the unit in extremely  
hot locations such as near or on top of radiators or other home heating devices. Its  
location among the user’s home audio components is not critical.  
POWER REQUIREMENTS  
The SLP-308 is designed to operate from AC house current mains. The design voltage is  
120 Volts AC at 50/60 Hz. Export units have settings for 100/200/220/240 Volts AC at  
50/60 Hz.  
 
INTERCONNECT CABLES  
The interconnect cables from the output jacks of the SLP-308 to the input jacks on the  
power amplifier can be any convenient length your set up requires. The choice of a high  
quality interconnect cable is important. Your Authorized Cary Audio Design Dealer will  
have proper interconnect cables in stock for this purpose. The low output impedance of  
the SLP-308 will run long interconnect wire runs, as long as 30-40 ft., without a  
problem. We suggest wires with good shielding if you live near transmitter towers for  
TV or radio stations.  
OPERATION  
Your new SLP-308 preamplifier is ready for operation after the various interconnect  
cables have been installed and the unit is plugged into the household AC mains 120 Volt  
AC wall socket. The SLP-308 is provided with functional, useful front panel controls  
with an attractive and logical layout.  
POWER SWITCH  
The toggle power switch is located at the left side on the SLP-308 preamplifier front  
panel. The switch operates in the following manner:  
OFF (Down position) Removes all AC voltages from the SLP-308 power supply.  
ON  
(Up position) Turns on the AC voltage to the power transformer primary  
on. The power transformer has a 200% duty cycle. In simple terms,  
the transformer is capable of operating two (2) SLP-308 preamplifiers  
continuously 24 hours a day. We recommend that the AC power  
switch be left in the ON position at all times. The SLP-308 sounds  
much better after 100 hour burn in and when warmed up for _ hour.  
Operate LED This blue LED will light after the SLP-308 is warmed up and  
biased properly.  
VOLUME CONTROL  
The gain of both left and right channels is controlled simultaneously by this control. The  
control potentiometer is of such high quality that the tracking error is less than 0.5 dB  
from 0 to -60 dB. The program source remains in balance over the entire range of this  
control. The taper rate of the volume control has been chosen to provide a rapid  
increase in gain over the first half of rotation and slower gain increase above 12:00  
position. The volume pot is controlling the input signal to the first grids of the 12AU7  
tubes. The volume control has a DC motor attached for remote operation. The blue  
LED in the volume knob is confirmation at a glance as to the overall level when you are  
too far away to read the output level meters.  
 
SELECTOR SWITCH  
The 4-position rotary switch connects a choice of input program source, both channels  
simultaneously. All program line sources are selected from this front panel 4 position  
switch. As you switch from source to source inputs, you will hear a soft mechanical  
clicking sound. This is normal and proper. The clicking sound is from the double pole,  
double throw (DPDT) gold plated relays switching input positions.  
WARNING!!!  
MAKE NO ATTEMPT TO PUT THE SLP-308 INTO SERVICE WITH THE  
TOP OFF OR THE CABINET OPEN. NEVER OPERATE THE SLP-308  
WITH THE TOP COVER REMOVED. CONTACT WITH THE  
OPERATING VOLTAGES PRESENT INSIDE THE SLP-308 CAN BE  
FATAL!  
FACTORY SERVICE  
If it becomes necessary to replace any parts in the SLP-308, the same brand and part  
number and style should be used. New parts are available from Cary Audio Design, Inc.  
1020 Goodworth Drive, Apex, North Carolina, 27539.  
Careful consideration has been given to the design of your new SLP-308 preamplifier to  
keep maintenance problems to a minimum; however, it is possible that some problems  
may arise. If this occurs, we suggest contacting our Customer Service Department at  
phone number 919-355-0010 from 1 to 5 PM, East Coast time to describe your  
problem in detail. Do not return the SLP-308 to the factory without a Return  
Authorization Number (RMA number) from the Customer Service Department. As the  
packing and shipping is being done by others, Cary Audio Design will assume no  
responsibility if the transportation company refuses to pay a damage claim due to your  
improperly packing or for lack of insurance should the unit be lost or damaged in  
shipment from you to us.  
 
SPECIAL NOTE:  
Your new SLP-308 preamplifier is a polarity inverting design. This means that a positive  
direction musical signal coming into the SLP-308 will be polarity inverted as it is  
amplified and be sent to the power amplifier as a negative direction signal. The SLP-308  
has one gain stage and one buffer stage in each channel. Absolute polarity inversion is  
common on many high-end preamplifiers. If you are concerned about ‘Absolute Phase’  
in your system, reverse the positive and negative leads either on the back of BOTH  
loudspeakers or at BOTH the speaker output terminals of your power amplifier.  
Remember to do this for both channels. However, please remember to switch the  
phasing only at the amplifier or only at the loudspeaker, not at both places. Operating in  
the polarity inverted phase mode will not harm anything.  
Cary Audio Design  
1020 Goodworth Drive  
Apex, North Carolina 27539  
Tel: 919-355-0010  
Fax: 919-355-0013  
 

Black Decker Oven CTO600 User Manual
Bose Speaker System 15 User Manual
Brother All in One Printer 4100e User Manual
Carrier Gas Heater 48HC User Manual
Carrier Refrigerator 30GTN015 035 User Manual
Casablanca Fan Company Fan 54028 User Manual
Casio Cash Register PCR T2100 User Manual
Christie Digital Systems Projector HD+30K User Manual
Chromalox Electric Heater PG405 5 User Manual
Cisco Systems Network Card CFP 100G LR4 User Manual